Converting Your Loft Without Planning Permission
Loft conversions can be an excellent way to add space and value to your home without extending the footprint of your property. Many loft conversions can be carried out under Permitted Development (PD) rights, which means you won't need to apply for planning permission, saving you time and money.
However, PD rights for loft conversions have specific volume and design limitations that you need to follow. This guide explains these rules in detail and helps you understand if your loft conversion project qualifies.
This guide reflects current regulations for England as of April 2025. Rules in Wales, Scotland, and Northern Ireland may differ. Always check with your local planning authority for the most up-to-date information specific to your area.
Types of Loft Conversions

Common types of loft conversions (from left to right): Roof windows only, rear dormer, and hip-to-gable with rear dormer
There are several types of loft conversions that can potentially be done under Permitted Development rights:
Roof Windows & Skylights
The simplest type of loft conversion involves installing roof windows or skylights into the existing roof slope without significantly altering the roof structure.

Key Features:
- Least intrusive type of loft conversion
- Minimal structural changes required
- Generally the most straightforward for Permitted Development
- Typically the most affordable option
PD Considerations:
- Must not extend higher than the highest part of the existing roof
- No extension beyond the existing roof plane on the front elevation
- The total volume addition still counts toward your allowance (40-50m³ depending on property type)
Roof windows typically provide less usable floor space than dormers because of the sloping ceiling, but they allow more natural light. Consider installing multiple roof windows to maximize light.
Dormer Windows
Dormer windows are vertical windows that project from the slope of the roof. They create additional headroom and usable floor space, making them one of the most popular loft conversion types.

Key Features:
- Creates vertical walls and increased headroom
- Can be built on the rear, side, or occasionally front of the property
- Single dormers or full-width "box dormers" are possible
- Maximizes usable floor space
PD Considerations:
- Must not extend higher than the highest part of the existing roof
- No extension beyond the roof plane on the front elevation (facing a highway)
- Minimum of 20cm set back from the eaves
- Materials should be similar in appearance to the existing house
- Must not include a veranda, balcony, or raised platform
- Side-facing windows must be obscure-glazed and non-opening below 1.7m from the floor
Box dormers often utilize most or all of your volume allowance (40-50m³). Calculate the volume carefully using our Roof Volume Calculator to ensure compliance.
Hip-to-Gable Conversions
In a hip-to-gable conversion, a sloping side roof (hip) is extended to create a vertical wall (gable), maximizing internal space. This is particularly common on semi-detached and end-of-terrace properties.

Key Features:
- Replaces a sloped hip roof with a vertical gable wall
- Often combined with a rear dormer for maximum space
- Typically only suitable for end-of-terrace or semi-detached properties with a hip roof
- Significant increase in usable floor area
PD Considerations:
- Volume additions must not exceed limits (40m³ for terraced houses, 50m³ for detached and semi-detached)
- Must not extend higher than the highest part of the existing roof
- Materials should match the existing house
- Side-facing windows must be obscure-glazed with openings at least 1.7m above floor level
- Cannot be used on the front elevation in most cases
Hip-to-gable conversions can significantly change the appearance of your property. While they're generally allowed under PD rights, they work best when they complement the existing architectural style of your home and street.
Mansard Conversions
Mansard conversions feature a flat roof with a steep sloped wall (typically at 72 degrees) and windows set into the slope or in small dormers. They typically extend across the entire width of the property.

Key Features:
- Provides maximum headroom and usable space
- Named after the 17th-century French architect François Mansart
- Common in urban areas, especially on terraced properties
- Creates a nearly vertical wall with a flat top roof
Mansard conversions typically require planning permission and do not usually fall under Permitted Development rights. This is because they significantly alter the roof shape and structure. If you're interested in a mansard conversion, you'll likely need to submit a full planning application.
Mansard conversions are particularly common in urban areas where they're an established architectural feature, such as in certain parts of London. Planning authorities may be more amenable to mansard conversions in these areas.
Permitted Development Volume Allowances
The key limitation for loft conversions under Permitted Development rights is the additional roof space volume you can create:
Property Type | Maximum Additional Volume |
---|---|
Terraced house | 40 cubic meters |
Semi-detached house | 50 cubic meters |
Detached house | 50 cubic meters |
The volume allowance applies to the total roof space additions, including any previous loft conversions by former owners. Use our Roof Volume Calculator to check if your planned conversion falls within the allowances.
General Restrictions for Loft Conversions
Height Restrictions
- Cannot be higher than the highest part of the existing roof
- No extension beyond the existing roof plane on the front elevation
- Dormer windows should be set back at least 20cm from the eaves
Privacy Requirements
- Side-facing windows must be obscure-glazed
- Any opening in side-facing windows must be at least 1.7m above the floor
- No balconies, verandas, or raised platforms
Excluded Properties
- Listed buildings
- Properties where PD rights have been removed
- Flats and maisonettes (no PD rights for loft conversions)
Appearance
- Materials must be similar to the existing house
- The conversion should match the existing roof style where possible
- More restrictions in Conservation Areas and Areas of Outstanding Natural Beauty
Building Regulations for Loft Conversions
While your loft conversion may not need planning permission, it will definitely require Building Regulations approval. This ensures the conversion is structurally sound, safe, and energy-efficient.
Key Building Regulations considerations include:
- Structural Integrity: The existing floor may need reinforcement to support the new living space
- Fire Safety: Requirements for fire-resistant doors, walls, floors, and escape routes
- Stairs: Specific requirements for headroom, width, and steepness
- Insulation: Minimum standards for thermal insulation
- Sound Insulation: Requirements for noise reduction between floors
- Windows and Ventilation: Requirements for natural light and ventilation
Loft Conversion in Special Areas
If your property is in a designated area, additional restrictions may apply:
- Conservation Areas: No roof extensions on the front or side slopes facing a highway
- Areas of Outstanding Natural Beauty (AONB): Maximum additional volume limited to 10m³ for terraced houses and 20m³ for detached and semi-detached houses
- National Parks: Similar restrictions to AONBs
- Listed Buildings: No Permitted Development rights - full planning permission and Listed Building Consent required
This guide focuses on England's Permitted Development rights. Regulations in Wales, Scotland, and Northern Ireland have similarities but important differences. Always check with your local planning authority for region-specific guidance.